St. Louis based · Serving the Midwest and across the country
Refinery and chemical process columns and piping
Barben Analytical · An AMETEK company

Barben Analytical pH, ORP, Conductivity and Oxygen Measurement

Process analytical sensors and optical oxygen analyzers for harsh industrial service. We help you choose the right sensor, mounting and materials for your application.

What Barben Analytical Provides

Barben Analytical makes process sensors and analyzers for measurements that are hard on equipment: sulfides, H2S, high solids, strong acids and bases, high pressure and high temperature.

Barben pH sensors are proven with analyzers from Rosemount, ABB, Foxboro, Endress+Hauser, Mettler Toledo, GLI/Hach and Knick; conductivity sensors with Rosemount, ABB, Endress+Hauser, Mettler Toledo and Knick.

  • pH and ORP sensors with the patented Axial Ion Path reference
  • Two- and four-electrode contacting conductivity sensors
  • OXYvisor optical oxygen analyzer for gas and liquid service, from trace ppm to percent levels
  • Sensors that work with most major analyzers, so you can upgrade the sensor and keep your electronics

Product Families

Barben Performance Series pH and ORP sensors
Performance Series

pH / ORP Sensors

Combination pH/ORP electrodes for harsh industrial measurement, built around the patented Axial Ion Path reference.

  • Reference designed to resist poisoning and plugging
  • Specialized glass for strong acids and bases, plus coating- and silica-resistant options
  • In-line to 2500 psig; quick change and retractable hot tap to 300 psig
  • Process temperature to 266°F (130°C)
Barben two-electrode and four-electrode conductivity sensors
Two & Four Electrode

Conductivity Sensors

Contacting conductivity sensors for pure water through high-conductivity processes.

  • Two-electrode sensors for pure water and low to medium conductivity
  • Four-electrode sensors for medium to high conductivity, a low-cost alternative to toroidal sensors
  • Extra electrode pair compensates for particulate and scale build-up
  • Threaded in-line, submersible and hot tap retractable options
Barben OXYvisor optical oxygen process analyzer
OXYvisor

Optical Oxygen Analyzers

Optical oxygen measurement in gas and liquid applications, from trace ppm to percent levels.

  • Quenched-luminescence measurement specific to oxygen
  • Detection limit 0.5 ppm O2 in gas (1 atm, 20°C) and 1 ppb dissolved O2
  • Auto-calibration, remote validation and datalogging
  • NEMA 4X / IP66 field-mountable enclosure

Find a Solution by Application

Applications documented for Barben Analytical products.

Industries Served

Water & Wastewater Treatment

pH and ORP sensors for municipal coagulation, aeration basins and outfall monitoring.

View industry

Biosolids

Optical oxygen analyzers for digester gas and pH sensors for H2S scrubbers.

View industry

Chemical Processing

pH and ORP measurement for chlor-alkali brine, titanium dioxide and VCM/PVC processes.

View industry

Oil & Gas Refining

pH, conductivity and optical oxygen measurement for refinery units, natural gas production and produced water.

View industry

Food & Beverage Processing

pH sensors for sugar processing.

View industry

Petrochemical Processing

pH and ORP measurement in VCM production, where ethylene and chlorine form EDC.

View industry

Oil & Gas Midstream

pH and optical oxygen measurement for gas sweetening and produced water at gas processing plants.

View industry

Power Generation & Utilities

pH sensors for wet FGD scrubbers and pH and oxygen measurement for biogas and RNG.

View industry

Pulp & Paper

pH and ORP sensors for chlorine dioxide bleaching and wet end stock preparation.

View industry

Renewable Energy & Biofuels

pH sensors for H2S scrubbers and optical oxygen analyzers for digester gas and sales-grade RNG.

View industry

Plastics, Polymers & Rubber Manufacturing

pH and ORP measurement across VCM and PVC production and wastewater.

View industry

Municipal & Government Infrastructure

pH and ORP sensors for municipal coagulation, aeration basins and outfalls.

View industry

Environmental Monitoring & Remediation

pH and optical oxygen measurement for FGD scrubbers, vapor recovery units, biogas and wastewater outfalls.

View industry

Featured Products

Barben Analytical Questions

What is the difference between the Barben 546, 547 and 551 sensors?

The Model 546 installs threaded in-line, submersible or through a high-pressure hot tap on a 3/4 inch NPT process connection. The Model 547 is a replaceable cartridge-style sensor for direct insertion and hot tap retractable installations where a sample line isn't practical. The Model 551 comes out for cleaning or calibration through a Nut Lock adapter that threads into a 1 inch NPT process connection.

Does the OXYvisor measure dissolved oxygen?

Yes. The OXYvisor uses quenched-luminescence measurement specific to oxygen. Its detection limit is 0.5 ppm O2 in gas (1 atm, 20 °C) and 1 ppb dissolved O2, in a NEMA 4X / IP66 field-mountable enclosure.

What pressure and temperature can Barben pH/ORP sensors handle?

In-line installations are rated to 2500 psig. Quick change and retractable hot tap installations are rated to 300 psig. Process temperature is rated to 266 °F (130 °C).

How do I replace an existing Barben sensor?

Send us the model number and a photo of the sensor or its label, and tell us how it is installed. We will match the replacement and quote it.

Application help

Need help selecting a Barben sensor?

Tell us what you're measuring, the process media, temperature, pressure and how the sensor will be installed. Replacing a sensor? Send the make and model of your analyzer. If you don't know an answer, mark it unknown.

pH, ORP, conductivity or oxygenProcess mediaNormal & max temperatureNormal & max pressureInstallation styleExisting analyzer make & modelPhotos of the installation
Download the Quote Checklist

Request a Quote or Contact Adaptive

Adaptive Industrial Solutions
1015 Grupp Road #31733
St. Louis, MO 63131
877.818.5009
sales@adaptiveind.com